$ @alia_com:define_commands !defines alia/sac/babyscan stuff $ @base:[control]define_idl_commands !defines idl stuff
Once you've put these in your login.com (and executed it in any
existing windows), you will have a number of useful commands defined.
You must have these commands defined for the remaining instructions
to work.
Back to Top
Type SCAN .
You will be prompted for the scan disk and filename to use.
If it has a standard filename and the filename indicates it
is a 1mm plate, you'll also be prompted to measure the upper
focus in the center of the plate, and then instructed how to
set the upper and lower focus dials. You'll be prompted for
the photometric setup values that you used to enter in the
TP_NML file. You will be given the option to set the
fiducial, and measure the fat zero.
In another window, invoke IDL and run the extensive focus tests to determine the appropriate focus settings.
Then, in the ALIA window, type SCAN/SET_FOCUS
or, SCAN/FOCUS=ADHOC . You will be prompted to enter the focus
settings that you determined with the IDL focus test.
Everything else will be the same.
Type SCAN/FOCUS=FLAT .
You'll be instructed how to set the lower focus, and prompted to enter the setting for the upper focus. Everything else will be the same.
Note that if you are doing a production scan of an ER plate, you don't need to say SCAN/FOCUS=FLAT . The fact that the filename will start with the letters ER will tell ALIA that it is a flat plate.
If the SAC comes up, shows the "Booting" message, but then goes down again (leaving the displays apparently frozen), examine the file ALIA_DATA:SAC.LOG. If it contains messages such as "ack, qio error occurred", then there may be an initialization problem with the Micro488a controller (the little black box that interfaces between TTA2 and the servo box).
To remedy this, get into hw_idl and type ieee_init . This should clear the abnormal condition of the controller. When it completes, try START_SAC again.
[The following is no longer needed for routine scanning, but is included here for reference.]To get baby_scan idl, do the following:
$ BABY_SCAN_PLACE $ SETUP_HW_IDL $ IDL HW_IDL >
Note, these are somewhat incompatible. You can't just execute them both in advance and then have idl hw_idl mean one thing, and widl the other thing. Someday we hope to fix this.
If any errors occur during a scan, the time and location of the errors is recorded in a rrrrr_pppp_nn.ERRORS file on the scan disk. Furthermore, a mail message is sent to the distribution contained in alia_data:error_scan.dis, advising that errors have occurred and careful visual qa should be performed on those regions.
It also includes a few other items:
Vicki Laidler -- laidler@stsci.edu